About Ober-Read

Laing Thermotech INFINITY Series Flow-Through heaters for OEM applications

[ Home] [ Laing AC Pump Products] [ Laing DC Pump Products ]

SEH Series

Rated for applications from
2.1 to 5.5 kW (230 V)
1.05 to 2.75 kW (115V)

Low Watt Density (30-80 watts/sq-in)
Provides greater element life
due to lower watt density

Constructed of corrosion resistant materials
316L Stainless Steel manifold
825 Incolloy sheath surrounding element

Total tube length of 42", can be bent
and shaped to fit your OEM machine
fit requirements.

Maximum working (system) pressure
30 psi (2 bar)

Maximum fluid temperature
140 deg F (60 deg C)

115V Performance Below

KW Output Amps Volts Watt Density Weight
2.75 23.0 115 37 7
2.05 17.0 115 28 7
1.35 11.2 115 18 7
1.05 8.8 115 14 7

230 V Performance Below

KW Output Amps Volts Watt Density Weight (lbs)
5.5 23.0 230 74 7
4.1 17.0 230 55 7
2.7 11.2 230 36 7
2.1 8.8 230 28 7

 

 

 

 

 

 

   

SHH Series

Rated for applications from
2.1 to 5.5 kW (230 V)
0.5 to 1.5 kW (115V)

Low Watt Density (28-90 watts/sq-in)
Provides greater element life
due to lower watt density

Constructed of corrosion resistant materials
316L Stainless Steel manifold
825 Incolloy sheath surrounding element

Tube length varies with heater rating.
See chart below for standard lengths.
All units above 1200 W can be bent
and shaped to fit your OEM requirement

Maximum working (system) pressure
30 psi (2 bar)

Maximum fluid temperature
140 deg F (60 deg C)

115V Performance Below

Watt Output

Amps

Volts

Watt Density

Weight (lbs)

Tube Length (in)

500

4.3

115

90

4

8

1000

8.7

115

90

4

11

1200

10.4

115

90

4

12

1500

13.0

115

90

4

14

230V Performance Below

Watt Output Amps Volts Watt Density Weight (lbs) Tube Length (in)
2100 8.8 230 28 6.5 40
2700 11.2 230 36 6.5 40
4100 17.0 230 55 6.5 40
5500 23.0 230 74 6.5 40
 

[ Home] [ Laing AC Pump Products] [ Laing DC Pump Products ]